Castle Care-Tech - Manufacturers of Intruder Alarms


Euro Insite 2008

Home > Products > Euro-MERiDIAN > PC Software > InSite


   Intruder Alarms:
   Euro-MERiDIAN    
      'ONE' Range (EN50131)
     Key Features
        Euro ONE
        Euro ONEplus
        Euro ONE 44
        Euro ONE IP
        Euro Mini
        Euro Mini Prox
           MSX Cards
        Legacy Euro
         Access Control
         PC Software
         Accessories
         iD Plus
  TouchScreen Keypad
          Flush Keypad
        ARM®
    Wireless / Radio
   Legacy Panels    
   Warning Devices:
   External Siren
   Castle care-Call
   Signalling Devices:
   SmartCom IP TCP
   COM9600 DigiModem

Win XP compliant
Win Vista compliant
Win 7 compliant

Castle Care-Tech take security one step further with the ability to remotely access your security systems from an office PC with InSite Downloading. This highly acclaimed product has won two prestigious International Awards: The European Security Innovation Award 1993, and The IFSEC Prism of Excellence 1994.

Euro InSite 2008 is the latest version of this software...

WHAT EXACTLY IS DOWNLOADING..?

InSite is Castle's own Windows™ based PC programme that allows authorised remote access via a modem to an alarm control panel. The exchange of information between the PC and the control panel is called 'Downloading'.

InSite is unique in that the information exchanged in not only alarm events, but also potential faults including the entire electrical status of the systems, down to the nut & bolt level.

This enables the alarm company to maintain a more efficient and cost effective service to clients.




 Database
A full database is available within InSite with all facilities including search, view and edit. Each site can be programmed in minutes, saving engineering time and minimising the chances of mistakes. alterations and additions are simply via the PC, without the need to send an engineer to site. click here to view a full screenshot

 Diagnostics
The Alarm Systems status, down to 'nut-and-bolt' level, is shown clearly. Outputs can be switched on and off remotely. A full service can be automatically performed, recorded and compared with the commissioning readings. Component degradation will be picked up instantly if and when it occurs. click here to view a full screenshot

 Support
As with all our products, InSite 2008 is backed up by full support by our technical team. Detailed manuals are provided on disk, and there is even a full 'help' guide to assist you through programming, complete with step-by-step pictures. click here to view a sample help screen

 System Logs
Complete logs can be uploaded from the panel, and printed in 'real', easy-to-understand English. Advanced filters can be set-up to display only the items you want to see and is fully searchable. Each log entry is accurately time and date-stamped. click here to view a full screenshot

ADVANCED FEATURES WITH INSITE PLUS

Upgrade your software to InSite 2008 Plus to gain the additional benefits.

(Please note this software is 'dongle' protected)



 User Access
Keep sensitive data secure. Each of your employess can have their own separate account within the software, with each account being fully customisable. Any one of InSite's programming options can be restricted or allowed for each user of the system. Access to the programme will require a log-in name and a password. click here to view a full screenshot

 Live Event Reporting
Keep instant tabs on all of your insalled alarm systems by having them dial into your office PC when any of the followinf events take place: Faults, alarms, access control events, set/unset events. Each panel can be configured to send only the information you wish to receive.
All events can be configured with their own unique colour for quick identification of important events, and are time and date stamped.
click here to view a full screenshot

 Increases Diagnostic Power
InSite Plus allows all the standard diagnostic features plus multiple diagnostic snapshot capabilities (can be saved and printed for use at a later date) and output switching. The new ouput switching lets you test all the outputs of the system remotely, including STU communications, and external SAB. click here to view a sample help screen

 Remote Set/Unset
Set or unset a remote alarm panel (any areas) from your office PC. To maintain site security, this facility can be restricted to certain PC users only. click here to view a full screenshot

 Soak Control
Zones can be put on and off soak remotely for test purposes. The amount of time for the soak period is fully programmable. click here to view a full screenshot

EUR‑050 Euro InSite 2008 software (installer's software) on CD-ROM for Windows XP and Vista. Full manual and help files included on CD-ROM. Dongle optional for increased functionality. Insite Installation Disk
EUR‑073 Slot-in ARM DigiModem for all Euro-MERiDIAN panels, enables panel to communicate on PSTN phone line. Digi ARM
EUR‑054 RS232 Interface Card and loom; enables panel to communicate with your PC through RS-232 serial port. For use with Euro G2 or G3 endstations and Euro-10,12,22,28,44 RS232 Card
EUR‑055 RS232 loom; for connecting a Euro Panel to a PC. RS232 Loom
EUR‑USB/SERIAL Serial to USB converter, for use with laptops and PCs which do not have an RS-232 serial port (works with EUR-055).
Comes complete with CD of drivers for windows operating systems.
RS232 to Serial Converter

Supported Platforms (Operating Systems):

XP Home, Professional
Vista
Windows 7 32-bit operating systems

Do not install InSite on Windows 7 64-bit operating systems.
CD-ROM and Manual
Up/Downloading PC Software


   Downloads
   InSite Software Download
   USB to SERIAL adaptor driver
   Latest Dongle Driver
   InSite Glossy Literature
   Operating Manual
   Migrating InSite Data
   Finding Windows Device Manager
   How InSite works over an IP Network
   Installing InSite on Vista
   Alternative dongle driver Driver
   Related Links
   Communication Devices
   Automatic Remote Maintenance
   Check for InSite Updates

ARM is DD263 Compliant

Valid HTML 4.01 Transitional


Return to the Home Page