Released in October 2005, our panel designed to meet all the requirements of EN50131-3 and suitable for use in systems designed to comply with PD6662:2004 at Grades 2 and 3.
The Castle Care-Tech range of intruder detection control systems is designed for the smallest domestic home right through to the largest commercial applications, all through the use of the G3 Plus panel which can be upgraded with 'snap-in' MSX cards to expand system capabilities all the way to 256 zones, 14 independant areas, up to 30 keypads and suitable for use in Grade 3 systems.
The benefits of the G3 Plus are that it can be wired in both iD and EoL mode, has pluggable terminal blocks for ease of wiring and a STU footprint for plug-on digital communicators.
| Zones |
|
74 (iD or EoL Mode available) |
| Keypads |
|
Max 8 |
| Tag Readers |
|
Max 7 |
| Access Control Points |
|
Max 7 = Total Not to Exceed 8 devices |
| Partitions |
|
4 areas or levels |
| Wards |
|
Max 7 |
| Shunts |
|
Max 30 |
| Codes |
|
100 (+20 Duress/Guard) |
| Programmable Outputs |
|
EoL Mode: 13 to 116 + Speaker ¦ iD Mode: 13 to 100 + speaker |
| Output Modules |
|
4 |
| ZEMs |
|
EoL Mode: 6 (8 zone ZEM) ¦ iD Mode: 2 (8 zone ZEM) |
| Logs |
|
2000 |
| EN Grade |
|
3 |
|
| Zones |
|
134 (Click here for Zone Map) |
| Keypads |
|
Max 16 |
| Tag Readers |
|
Max 16 |
| Access Control Points |
|
Max 29 = Total Not to Exceed 30 devices |
| Partitions |
|
8 areas or 8 levels |
| Wards |
|
Max 29 |
| Shunts |
|
Max 64 |
| Codes |
|
230 (+20 Duress/Guard) |
| Programmable Outputs |
|
EoL Mode: 13 to 256 + Speaker ¦ iD Mode: 13 to 212 + speaker |
| Output Modules |
|
8 |
| ZEMs |
|
EoL Mode: 14 (8 zone ZEM) ¦ iD Mode: 3 (30 zone ZEM) |
| Logs |
|
2000 |
| EN Grade |
|
3 |
| Zones |
|
256 (Click here for Zone Map) |
| Keypads |
|
Max 16 |
| Tag Readers |
|
Max 16 |
| Access Control Points |
|
Max 29 = Total Not to Exceed 30 devices |
| Partitions |
|
14 areas or 14 levels |
| Wards |
|
Max 29 |
| Shunts |
|
Max 128 |
| Codes |
|
500 (+20 Duress/Guard) |
| Programmable Outputs |
|
EoL Mode: 13 to 320 + Speaker ¦ iD Mode: 13 to 228 + speaker |
| Output Modules |
|
8 |
| ZEMs |
|
EoL Mode: 30 (8 zone ZEM) ¦ iD Mode: 7 (8 zone ZEM) |
| Logs |
|
2500 |
| EN Grade |
|
3 |
|
| OUTPUT CAPABILITIES |
| Hold Off: |
|
650 mA (continuous) Max 800 mA in alarm |
| Outputs 1 & 2: |
|
800 mA |
| Output 3: |
|
100 mA |
| Output 4 |
|
100 mA |
| Relay (A): |
|
3 Amp (Volt-free Change-over contacts) |
| Loudspeaker |
|
Max load 8 ohms Suitable for 1x8 ohm or 2x16 ohm speakers |
| 'STU' Pins |
|
1 mA |
| 12v outlets |
|
800 mA 300mA on ZEM |
| Electrical Specifications |
| Mains Supply: |
|
230v (220-240v) AC Max 250mA |
| Power Supply: |
|
13.75v DC 2.5 Amp (1.5A continuous) |
| Battery: |
|
17Ah |
| Fuses: |
|
|
| Battery: |
|
3.15A Quick Blow |
| 12v outlets: |
|
800mA Quick Blow |
|